All Publications
Data provided by
UCSF Profiles, powered by
CTSI at UCSF
- Santandreu AG, Taheri-Tehrani P, Feinberg B, Torres A, Blaha C, Shaheen R, Moyer J, Wright N, Szot GL, Fissell WH, Vartanian S, Posselt A, Roy S. Characterization of human islet function in a convection-driven intravascular bioartificial pancreas. Bioeng Transl Med. 2023 Mar; 8(2):e10444. View in PubMed
- Blauvelt DG, Chui BW, Higgins NC, Baltazar FJ, Roy S. Silicon membranes for extracorporeal life support: a comparison of design and fabrication methodologies. Biomed Microdevices. 2022 12 06; 25(1):2. View in PubMed
- Hunter K, Larsen JA, Love HD, Evans RC, Roy S, Zent R, Harris RC, Wilson MH, Fissell WH. Inhibition of Transforming Growth Factor-β Improves Primary Renal Tubule Cell Differentiation in Long-Term Culture. Tissue Eng Part A. 2023 02; 29(3-4):102-111. View in PubMed
- Love H, Evans R, Hunter K, Roy S, Fissell WH. Functionalizing Polyacrylamide Hydrogels for Renal Cell Culture Under Fluid Shear Stress. Tissue Eng Part A. 2022 10; 28(19-20):845-854. View in PubMed
- Groth T, Stegmayr BG, Ash SR, Kuchinka J, Wieringa FP, Fissell WH, Roy S. Wearable and implantable artificial kidney devices for end-stage kidney disease treatment: Current status and review. Artif Organs. 2023 Apr; 47(4):649-666. View in PubMed
- Conway PT, Gedney N, Roy S, Fissell WH. The Advancing American Kidney Health Initiative: The Challenge of Overcoming the Status Quo. J Am Soc Nephrol. 2022 09; 33(9):1797-1798. View in PubMed
- Shaheen R, Gurlin RE, Gologorsky R, Blaha C, Munnangi P, Santandreu A, Torres A, Carnese P, Nair GG, Szot G, Fissell WH, Hebrok M, Roy S. Superporous agarose scaffolds for encapsulation of adult human islets and human stem-cell-derived β cells for intravascular bioartificial pancreas applications. J Biomed Mater Res A. 2021 12; 109(12):2438-2448. View in PubMed
- Sanger T, Chang A, Feaster W, Taraman S, Afari N, Beauregard D, Dethlefs B, Ghere T, Kabeer M, Tolomiczenko G, Billig M, Brophy J, Eskandanian K, Espinoza J, Farrugia S, Harrison M, Horvat C, Hoyen C, Koh C, Komiyama A, Nelson K, Kulkarni O, Levy R, Maher K, O'Donnell M, Ponsky T, Richmond F, Richter J, Roy S, Samir S, Suresh S, Stallworth C, Thekkedath U, Toman K, Wall J, West L, Wolff D. Opportunities for Regulatory Changes to Promote Pediatric Device Innovation in the United States: Joint Recommendations From Pediatric Innovator Roundtables. IEEE J Transl Eng Health Med. 2021; 9:4800105. View in PubMed
- Quesada O, Shandhi MMH, Beach S, Dowling S, Tandon D, Heller J, Etemadi M, Roy S, Gonzalez Velez JM, Inan OT, Klein L. Use of Ballistocardiography to Monitor Cardiovascular Hemodynamics in Preeclampsia. Womens Health Rep (New Rochelle). 2021; 2(1):97-105. View in PubMed
- Blauvelt DG, Abada EN, Oishi P, Roy S. Advances in extracorporeal membrane oxygenator design for artificial placenta technology. Artif Organs. 2021 Mar; 45(3):205-221. View in PubMed
- Love H, Evans R, Humes HD, Roy S, Zent R, Harris R, Wilson M, Fissell WH. Metformin and Inhibition of Transforming Growth Factor-Beta Stimulate In Vitro Transport in Primary Renal Tubule Cells. Tissue Eng Part A. 2020 10; 26(19-20):1091-1098. View in PubMed
- Hojs N, Fissell WH, Roy S. Ambulatory Hemodialysis-Technology Landscape and Potential for Patient-Centered Treatment. Clin J Am Soc Nephrol. 2020 01 07; 15(1):152-159. View in PubMed
- Yee C, McCoy D, Yu J, Losey A, Jordan C, Moore T, Stillson C, Oh HJ, Kilbride B, Roy S, Patel A, Wilson MW, Hetts SW, ChemoFilter Consortium. Endovascular Ion Exchange Chemofiltration Device Reduces Off-Target Doxorubicin Exposure in a Hepatic Intra-arterial Chemotherapy Model. Radiol Imaging Cancer. 2019 09 27; 1(1):e190009. View in PubMed
- Wilson MH, Veach RA, Luo W, Welch RC, Roy S, Fissell WH. Genome Engineering Renal Epithelial Cells for Enhanced Volume Transport Function. Cell Mol Bioeng. 2020 Feb; 13(1):17-26. View in PubMed
- Fissell WH, Roy S. Treating the kidneys - a new era in the United States (and beyond). Nat Rev Nephrol. 2019 12; 15(12):727-728. View in PubMed
- Gologorsky RC, Roy S. Ultrafiltration for management of fluid overload in patients with heart failure. Artif Organs. 2020 Feb; 44(2):129-139. View in PubMed
- Sarode DN, Roy S. In Vitro models for thrombogenicity testing of blood-recirculating medical devices. Expert Rev Med Devices. 2019 07; 16(7):603-616. View in PubMed
- Ferrell N, Sandoval RM, Molitoris BA, Brakeman P, Roy S, Fissell WH. Application of physiological shear stress to renal tubular epithelial cells. Methods Cell Biol. 2019; 153:43-67. View in PubMed
- Castle E, Chung P, Behfar MH, Chen M, Gao J, Chiu N, Nelson G, Roy S, Oberoi S. Compliance monitoring via a Bluetooth-enabled retainer: A prospective clinical pilot study. Orthod Craniofac Res. 2019 May; 22 Suppl 1:149-153. View in PubMed
- Jayagopal A, Brakeman PR, Soler P, Ferrell N, Fissell W, Kroetz DL, Roy S. Apical Shear Stress Enhanced Organic Cation Transport in Human OCT2/MATE1-Transfected Madin-Darby Canine Kidney Cells Involves Ciliary Sensing. J Pharmacol Exp Ther. 2019 06; 369(3):523-530. View in PubMed
- Iqbal Z, Kim S, Moyer J, Moses W, Abada E, Wright N, Kim EJ, Park J, Fissell WH, Vartanian S, Roy S. In vitro and in vivo hemocompatibility assessment of ultrathin sulfobetaine polymer coatings for silicon-based implants. J Biomater Appl. 2019 08; 34(2):297-312. View in PubMed
- Love HD, Ao M, Jorgensen S, Swearingen L, Ferrell N, Evans R, Gewin L, Harris RC, Zent R, Roy S, Fissell WH. Substrate Elasticity Governs Differentiation of Renal Tubule Cells in Prolonged Culture. Tissue Eng Part A. 2019 07; 25(13-14):1013-1022. View in PubMed
- Ferrell N, Cheng J, Miao S, Roy S, Fissell WH. Orbital Shear Stress Regulates Differentiation and Barrier Function of Primary Renal Tubular Epithelial Cells. ASAIO J. 2018 Nov/Dec; 64(6):766-772. View in PubMed
- Rao A, Huynh E, Royston TJ, Kornblith A, Roy S. Acoustic Methods for Pulmonary Diagnosis. IEEE Rev Biomed Eng. 2019; 12:221-239. View in PubMed
- Abada EN, Feinberg BJ, Roy S. Evaluation of silicon membranes for extracorporeal membrane oxygenation (ECMO). Biomed Microdevices. 2018 10 05; 20(4):86. View in PubMed
- Salani M, Roy S, Fissell WH. Innovations in Wearable and Implantable Artificial Kidneys. Am J Kidney Dis. 2018 11; 72(5):745-751. View in PubMed
- Rao A, Chu S, Batlivala N, Zetumer S, Roy S. Improved Detection of Lung Fluid With Standardized Acoustic Stimulation of the Chest. IEEE J Transl Eng Health Med. 2018; 6:3200107. View in PubMed
- Rao A, Ruiz J, Bao C, Roy S. Tabla: A Proof-of-Concept Auscultatory Percussion Device for Low-Cost Pneumonia Detection. Sensors (Basel). 2018 Aug 16; 18(8). View in PubMed
- Sneddon JB, Tang Q, Stock P, Bluestone JA, Roy S, Desai T, Hebrok M. Stem Cell Therapies for Treating Diabetes: Progress and Remaining Challenges. Cell Stem Cell. 2018 Jun 01; 22(6):810-823. View in PubMed
- Buck AKW, Groszek JJ, Colvin DC, Keller SB, Kensinger C, Forbes R, Karp S, Williams P, Roy S, Fissell WH. Combined In Silico and In Vitro Approach Predicts Low Wall Shear Stress Regions in a Hemofilter that Correlate with Thrombus Formation In Vivo. ASAIO J. 2018 Mar/Apr; 64(2):211-217. View in PubMed
- Buck AKW, Goebel SG, Goodin MS, Wright NJ, Groszek JJ, Moyer J, Singh S, Bluestein D, Fissell WH, Roy S. Original article submission: Platelet stress accumulation analysis to predict thrombogenicity of an artificial kidney. J Biomech. 2018 03 01; 69:26-33. View in PubMed
- Inan OT, Baran Pouyan M, Javaid AQ, Dowling S, Etemadi M, Dorier A, Heller JA, Bicen AO, Roy S, De Marco T, Klein L. Novel Wearable Seismocardiography and Machine Learning Algorithms Can Assess Clinical Status of Heart Failure Patients. Circ Heart Fail. 2018 01; 11(1):e004313. View in PubMed
- Feinberg BJ, Hsiao JC, Park J, Zydney AL, Fissell WH, Roy S. Slit pores preferred over cylindrical pores for high selectivity in biomolecular filtration. J Colloid Interface Sci. 2018 May 01; 517:176-181. View in PubMed
- Iqbal Z, Moses W, Kim S, Kim EJ, Fissell WH, Roy S. Sterilization effects on ultrathin film polymer coatings for silicon-based implantable medical devices. J Biomed Mater Res B Appl Biomater. 2018 08; 106(6):2327-2336. View in PubMed
- Dharia A, Abada E, Feinberg B, Yeager T, Moses W, Park J, Blaha C, Wright N, Padilla B, Roy S. Silicon Micropore-Based Parallel Plate Membrane Oxygenator. Artif Organs. 2018 Feb; 42(2):166-173. View in PubMed
- Song S, Blaha C, Moses W, Park J, Wright N, Groszek J, Fissell W, Vartanian S, Posselt AM, Roy S. Correction: An intravascular bioartificial pancreas device (iBAP) with silicon nanopore membranes (SNM) for islet encapsulation under convective mass transport. Lab Chip. 2017 06 27; 17(13):2334. View in PubMed
- Song S, Blaha C, Moses W, Park J, Wright N, Groszek J, Fissell W, Vartanian S, Posselt AM, Roy S. An intravascular bioartificial pancreas device (iBAP) with silicon nanopore membranes (SNM) for islet encapsulation under convective mass transport. Lab Chip. 2017 05 16; 17(10):1778-1792. View in PubMed
- Öberg CM, Groszek JJ, Roy S, Fissell WH, Rippe B. A distributed solute model: an extended two-pore model with application to the glomerular sieving of Ficoll. Am J Physiol Renal Physiol. 2018 06 01; 314(6):F1108-F1116. View in PubMed
- Feinberg BJ, Hsiao JC, Park J, Zydney AL, Fissell WH, Roy S. Silicon nanoporous membranes as a rigorous platform for validation of biomolecular transport models. J Memb Sci. 2017 08 15; 536:44-51. View in PubMed
- Song S, Yeung R, Park J, Posselt AM, Desai TA, Tang Q, Roy S. Glucose-Stimulated Insulin Response of Silicon Nanopore-Immunoprotected Islets under Convective Transport. ACS Biomater Sci Eng. 2017 Jun 12; 3(6):1051-1061. View in PubMed
- Yeager T, Roy S. Evolution of Gas Permeable Membranes for Extracorporeal Membrane Oxygenation. Artif Organs. 2017 Aug; 41(8):700-709. View in PubMed
- Brakeman P, Miao S, Cheng J, Lee CZ, Roy S, Fissell WH, Ferrell N. A modular microfluidic bioreactor with improved throughput for evaluation of polarized renal epithelial cells. Biomicrofluidics. 2016 Nov; 10(6):064106. View in PubMed
- Javaid AQ, Ashouri H, Dorier A, Etemadi M, Heller JA, Roy S, Inan OT. Quantifying and Reducing Motion Artifacts in Wearable Seismocardiogram Measurements During Walking to Assess Left Ventricular Health. IEEE Trans Biomed Eng. 2017 06; 64(6):1277-1286. View in PubMed
- Behfar MH, Abada E, Sydanheimo L, Goldman K, Fleischman AJ, Gupta N, Ukkonen L, Roy S. Inductive passive sensor for intraparenchymal and intraventricular monitoring of intracranial pressure. Annu Int Conf IEEE Eng Med Biol Soc. 2016 Aug; 2016:1950-1954. View in PubMed
- Kim S, Feinberg B, Kant R, Chui B, Goldman K, Park J, Moses W, Blaha C, Iqbal Z, Chow C, Wright N, Fissell WH, Zydney A, Roy S. Diffusive Silicon Nanopore Membranes for Hemodialysis Applications. PLoS One. 2016; 11(7):e0159526. View in PubMed
- Kensinger C, Karp S, Kant R, Chui BW, Goldman K, Yeager T, Gould ER, Buck A, Laneve DC, Groszek JJ, Roy S, Fissell WH. First Implantation of Silicon Nanopore Membrane Hemofilters. ASAIO J. 2016 Jul-Aug; 62(4):491-5. View in PubMed
- Song S, Faleo G, Yeung R, Kant R, Posselt AM, Desai TA, Tang Q, Roy S. Silicon nanopore membrane (SNM) for islet encapsulation and immunoisolation under convective transport. Sci Rep. 2016 Mar 24; 6:23679. View in PubMed
- Kim S, Heller J, Iqbal Z, Kant R, Kim EJ, Durack J, Saeed M, Do L, Hetts S, Wilson M, Brakeman P, Fissell WH, Roy S. Preliminary Diffusive Clearance of Silicon Nanopore Membranes in a Parallel Plate Configuration for Renal Replacement Therapy. ASAIO J. 2016 Mar-Apr; 62(2):169-75. View in PubMed
- Song S, Roy S. Progress and challenges in macroencapsulation approaches for type 1 diabetes (T1D) treatment: Cells, biomaterials, and devices. Biotechnol Bioeng. 2016 07; 113(7):1381-402. View in PubMed
- Harrison B, Stern L, Chung P, Etemadi M, Kwiat D, Roy S, Harrison MR, Martinez-Ferro M. MyPectus: First-in-human pilot study of remote compliance monitoring of teens using dynamic compression bracing to correct pectus carinatum. J Pediatr Surg. 2016 Apr; 51(4):608-11. View in PubMed
- Yang J, Charif AC, Puskas JE, Phillips H, Shanahan KJ, Garsed J, Fleischman A, Goldman K, Roy S, Luebbers MT, Dombrowski SM, Luciano MG. Corrigendum to: Biocompatibility evaluation of a thermoplastic rubber for wireless telemetric intracranial pressure sensor coating. J Mech Behav Biomed Mater. 2016 Jan; 53:463. View in PubMed
- Etemadi M, Inan OT, Heller JA, Hersek S, Klein L, Roy S. A Wearable Patch to Enable Long-Term Monitoring of Environmental, Activity and Hemodynamics Variables. IEEE Trans Biomed Circuits Syst. 2016 Apr; 10(2):280-8. View in PubMed
- Swisher SL, Lin MC, Liao A, Leeflang EJ, Khan Y, Pavinatto FJ, Mann K, Naujokas A, Young D, Roy S, Harrison MR, Arias AC, Subramanian V, Maharbiz MM. Impedance sensing device enables early detection of pressure ulcers in vivo. Nat Commun. 2015 Mar 17; 6:6575. View in PubMed
- Song S, Kim EJ, Bahney CS, Miclau T, Marcucio R, Roy S. The synergistic effect of micro-topography and biochemical culture environment to promote angiogenesis and osteogenic differentiation of human mesenchymal stem cells. Acta Biomater. 2015 May; 18:100-11. View in PubMed
- Yang J, Charif AC, Puskas JE, Phillips H, Shanahan KJ, Garsed J, Fleischman A, Goldman K, Roy S, Luebbers MT, Dombrowski SM, Luciano MG. Biocompatibility evaluation of a thermoplastic rubber for wireless telemetric intracranial pressure sensor coating. J Mech Behav Biomed Mater. 2015 May; 45:83-9. View in PubMed
- Kim S, Fissell WH, Humes DH, Roy S. Current strategies and challenges in engineering a bioartificial kidney. Front Biosci (Elite Ed). 2015 01 01; 7(2):215-28. View in PubMed
- Liao A, Lin MC, Ritz LC, Swisher SL, Ni D, Mann K, Khan Y, Roy S, Harrison MR, Arias AC, Subramanian V, Young D, Maharbiz MM. Impedance sensing device for monitoring ulcer healing in human patients. Annu Int Conf IEEE Eng Med Biol Soc. 2015; 2015:5130-3. View in PubMed
- Wiens AD, Etemadi M, Roy S, Klein L, Inan OT. Toward continuous, noninvasive assessment of ventricular function and hemodynamics: wearable ballistocardiography. IEEE J Biomed Health Inform. 2015 Jul; 19(4):1435-42. View in PubMed
- Chung P, Heller JA, Etemadi M, Ottoson PE, Liu JA, Rand L, Roy S. Rapid and low-cost prototyping of medical devices using 3D printed molds for liquid injection molding. J Vis Exp. 2014 Jun 27; (88):e51745. View in PubMed
- Olorunsola OG, Kim SH, Chang R, Kuo YC, Hetts SW, Heller A, Kant R, Saeed M, Fissell WH, Roy S, Wilson MW. Imaging assessment of a portable hemodialysis device: detection of possible failure modes and monitoring of functional performance. Med Instrum (Luton). 2014 Mar 27; 2(2). View in PubMed
- Etemadi M, Hersek S, Tseng JM, Rabbani N, Heller JA, Roy S, Klein L, Inan OT. Tracking clinical status for heart failure patients using ballistocardiography and electrocardiography signal features. Annu Int Conf IEEE Eng Med Biol Soc. 2014; 2014:5188-91. View in PubMed
- Wiens A, Etemadi M, Klein L, Roy S, Inan OT. Wearable ballistocardiography: preliminary methods for mapping surface vibration measurements to whole body forces. Annu Int Conf IEEE Eng Med Biol Soc. 2014; 2014:5172-5. View in PubMed
- Jiang H, Chen S, Kish S, Loh L, Zhang J, Zhang X, Kwiat D, Harrison M, Roy S. Miniaturizing RFID for magnamosis. Annu Int Conf IEEE Eng Med Biol Soc. 2014; 2014:638-41. View in PubMed
- Kim S, Roy S. Microelectromechanical systems and nephrology: the next frontier in renal replacement technology. Adv Chronic Kidney Dis. 2013 Nov; 20(6):516-35. View in PubMed
- Jiang H, Zhang J, Lan D, Liou S, Shahnasser H, Fechter R, Hirose S, Harrison M, Roy S. A low-frequency versatile wireless power transfer technology for biomedical implants. IEEE Trans Biomed Circuits Syst. 2013 Aug; 7(4):526-35. View in PubMed
- Etemadi M, Chung P, Heller JA, Liu JA, Rand L, Roy S. Towards BirthAlert--A Clinical Device Intended for Early Preterm Birth Detection. IEEE Trans Biomed Eng. 2013 Dec; 60(12):3484-93. View in PubMed
- Kim EJ, Fleischman AJ, Muschler GF, Roy S. Response of bone marrow derived connective tissue progenitor cell morphology and proliferation on geometrically modulated microtextured substrates. Biomed Microdevices. 2013 Jun; 15(3):385-96. View in PubMed
- Humes HD, Buffington D, Westover AJ, Roy S, Fissell WH. The bioartificial kidney: current status and future promise. Pediatr Nephrol. 2014 Mar; 29(3):343-51. View in PubMed
- Fissell WH, Roy S, Davenport A. Achieving more frequent and longer dialysis for the majority: wearable dialysis and implantable artificial kidney devices. Kidney Int. 2013 Aug; 84(2):256-64. View in PubMed
- Chung P, Rowe A, Etemadi M, Lee H, Roy S. Fabric-based pressure sensor array for decubitus ulcer monitoring. Annu Int Conf IEEE Eng Med Biol Soc. 2013; 2013:6506-9. View in PubMed
- Etemadi M, Chung P, Heller JA, Liu J, Grossman-Kahn R, Rand L, Roy S. Novel device to trend impedance and fluorescence of the cervix for preterm birth detection. Annu Int Conf IEEE Eng Med Biol Soc. 2013; 2013:176-9. View in PubMed
- Etemadi M, Heller JA, Schecter SC, Shue EH, Miniati D, Roy S. Implantable ultra-low pulmonary pressure monitoring system for fetal surgery. IEEE Trans Inf Technol Biomed. 2012 Nov; 16(6):1208-15. View in PubMed
- Jiang H, Lan D, Lin D, Zhang J, Liou S, Shahnasser H, Shen M, Harrison M, Roy S. A feed-forward controlled AC-DC boost converter for biomedical implants. Annu Int Conf IEEE Eng Med Biol Soc. 2012; 2012:1675-8. View in PubMed
- Jelin EB, Etemadi M, Encinas J, Schecter SC, Chapin C, Wu J, Guevara-Gallardo S, Nijagal A, Gonzales KD, Ferrier WT, Roy S, Miniati D. Dynamic tracheal occlusion improves lung morphometrics and function in the fetal lamb model of congenital diaphragmatic hernia. J Pediatr Surg. 2011 Jun; 46(6):1150-7. View in PubMed
- Muthusubramaniam L, Lowe R, Fissell WH, Li L, Marchant RE, Desai TA, Roy S. Hemocompatibility of silicon-based substrates for biomedical implant applications. Ann Biomed Eng. 2011 Apr; 39(4):1296-305. View in PubMed
- Li L, Marchant RE, Dubnisheva A, Roy S, Fissell WH. Anti-biofouling Sulfobetaine Polymer Thin Films on Silicon and Silicon Nanopore Membranes. J Biomater Sci Polym Ed. 2011; 22(1-3):91-106. View in PubMed
- Jiang H, Lan D, Goldman K, Etemadi M, Shahnasser H, Roy S. The Responsivity of a Miniaturized Passive Implantable Wireless Pressure Sensor. Proc IEEE Radio Wirel Symp. 2011; 2011:11-14. View in PubMed
- Ferrell N, Desai RR, Fleischman AJ, Roy S, Humes HD, Fissell WH. A microfluidic bioreactor with integrated transepithelial electrical resistance (TEER) measurement electrodes for evaluation of renal epithelial cells. Biotechnol Bioeng. 2010 Nov 01; 107(4):707-16. View in PubMed
- Ferrell N, Groszek J, Li L, Smith R, Butler RS, Zorman CA, Roy S, Fissell WH. Basal lamina secreted by MDCK cells has size- and charge-selective properties. Am J Physiol Renal Physiol. 2011 Jan; 300(1):F86-90. View in PubMed
- Chandrana C, Talman J, Pan T, Roy S, Fleischman A. Design and analysis of MEMS based PVDF ultrasonic transducers for vascular imaging. Sensors (Basel). 2010; 10(9):8740-50. View in PubMed
- Groszek J, Li L, Ferrell N, Smith R, Zorman CA, Hofmann CL, Roy S, Fissell WH. Molecular conformation and filtration properties of anionic Ficoll. Am J Physiol Renal Physiol. 2010 Oct; 299(4):F752-7. View in PubMed
- Melvin ME, Fissell WH, Roy S, Brown DL. Silicon induces minimal thromboinflammatory response during 28-day intravascular implant testing. ASAIO J. 2010 Jul-Aug; 56(4):344-8. View in PubMed
- Chandrana C, Kharin N, Vince G, Roy S, Fleischman A. Demonstration of second-harmonic IVUS feasibility with focused broadband miniature transducers. IEEE Trans Ultrason Ferroelectr Freq Control. 2010 May; 57(5):1077-85. View in PubMed
- Datta S, Conlisk AT, Kanani DM, Zydney AL, Fissell WH, Roy S. Characterizing the surface charge of synthetic nanomembranes by the streaming potential method. J Colloid Interface Sci. 2010 Aug 01; 348(1):85-95. View in PubMed
- Kanani DM, Fissell WH, Roy S, Dubnisheva A, Fleischman A, Zydney AL. Permeability - Selectivity Analysis for Ultrafiltration: Effect of Pore Geometry. J Memb Sci. 2010 Mar 01; 349(1-2):405. View in PubMed
- Jiang H, Zhang JM, Liou SS, Fechter R, Hirose S, Harrison M, Roy S. A high-power versatile wireless power transfer for biomedical implants. Annu Int Conf IEEE Eng Med Biol Soc. 2010; 2010:6437-40. View in PubMed
- Fissell WH, Roy S. The implantable artificial kidney. Semin Dial. 2009 Nov-Dec; 22(6):665-70. View in PubMed
- Kim EJ, Boehm CA, Fleischman AJ, Muschler GF, Kostov YV, Roy S. Modulating human connective tissue progenitor cell behavior on cellulose acetate scaffolds by surface microtextures. J Biomed Mater Res A. 2009 Sep 15; 90(4):1198-205. View in PubMed
- Fissell WH, Hofmann CL, Ferrell N, Schnell L, Dubnisheva A, Zydney AL, Yurchenco PD, Roy S. Solute partitioning and filtration by extracellular matrices. Am J Physiol Renal Physiol. 2009 Oct; 297(4):F1092-100. View in PubMed
- Kim EJ, Boehm CA, Mata A, Fleischman AJ, Muschler GF, Roy S. Post microtextures accelerate cell proliferation and osteogenesis. Acta Biomater. 2010 Jan; 6(1):160-9. View in PubMed
- Mata A, Kim EJ, Boehm CA, Fleischman AJ, Muschler GF, Roy S. A three-dimensional scaffold with precise micro-architecture and surface micro-textures. Biomaterials. 2009 Sep; 30(27):4610-7. View in PubMed
- Conlisk AT, Datta S, Fissell WH, Roy S. Biomolecular transport through hemofiltration membranes. Ann Biomed Eng. 2009 Apr; 37(4):722-36. View in PubMed
- Fissell WH, Dubnisheva A, Eldridge AN, Fleischman AJ, Zydney AL, Roy S. High-Performance Silicon Nanopore Hemofiltration Membranes. J Memb Sci. 2009 Jan 05; 326(1):58-63. View in PubMed
- Nath P, Strelnik J, Vasanji A, Moore LR, Williams PS, Zborowski M, Roy S, Fleischman AJ. Development of multistage magnetic deposition microscopy. Anal Chem. 2009 Jan 01; 81(1):43-9. View in PubMed
- Roy S, Fleischman A, Benzel EC, Cameron BD, Ferrara L, Goel VK. Basic Science Symposium II: MEMS Technology. SAS J. 2008; 2(2):120-9. View in PubMed
- Ferrara LA, Gordon I, Schlenk R, Coquillette M, Fleischman AJ, Roy S, Togawa D, Bauer TW, Benzel EC. In Vivo Assessment of Bone Graft/Endplate Contact Pressure in a Caprine Interbody Pseudarthrosis Model: A Preliminary Biomechanical Characterization of the Fusion Process for the Development of a Microelectromechanical Systems (MEMS) Biosensor. SAS J. 2008; 2(1):1-8. View in PubMed
- Ferrara LA, Gordon I, Coquillette M, Milks R, Fleischman AJ, Roy S, Goel VK, Benzel EC. A preliminary biomechanical evaluation in a simulated spinal fusion model. Laboratory investigation. J Neurosurg Spine. 2007 Nov; 7(5):542-8. View in PubMed
- Melnik K, Sun J, Fleischman A, Roy S, Zborowski M, Chalmers JJ. Quantification of magnetic susceptibility in several strains of Bacillus spores: implications for separation and detection. Biotechnol Bioeng. 2007 Sep 01; 98(1):186-92. View in PubMed
- Fissell WH, Manley S, Dubnisheva A, Glass J, Magistrelli J, Eldridge AN, Fleischman AJ, Zydney AL, Roy S. Ficoll is not a rigid sphere. Am J Physiol Renal Physiol. 2007 Oct; 293(4):F1209-13. View in PubMed
- Fissell WH, Fleischman AJ, Humes HD, Roy S. Development of continuous implantable renal replacement: past and future. Transl Res. 2007 Dec; 150(6):327-36. View in PubMed
- Mata A, Boehm C, Fleischman AJ, Muschler GF, Roy S. Connective tissue progenitor cell growth characteristics on textured substrates. Int J Nanomedicine. 2007; 2(3):389-406. View in PubMed
- Fissell WH, Manley S, Westover A, Humes HD, Fleischman AJ, Roy S. Differentiated growth of human renal tubule cells on thin-film and nanostructured materials. ASAIO J. 2006 May-Jun; 52(3):221-7. View in PubMed
- Smiechowski MF, Lvovich VF, Roy S, Fleischman A, Fissell WH, Riga AT. Electrochemical detection and characterization of proteins. Biosens Bioelectron. 2006 Dec 15; 22(5):670-7. View in PubMed
- Schneider T, Moore LR, Jing Y, Haam S, Williams PS, Fleischman AJ, Roy S, Chalmers JJ, Zborowski M. Continuous flow magnetic cell fractionation based on antigen expression level. J Biochem Biophys Methods. 2006 Jul 31; 68(1):1-21. View in PubMed
- Talman JR, Fleischman AJ, Roy S. Orthogonal-coil RF probe for implantable passive sensors. IEEE Trans Biomed Eng. 2006 Mar; 53(3):538-46. View in PubMed
- Lopez CA, Fleischman AJ, Roy S, Desai TA. Evaluation of silicon nanoporous membranes and ECM-based microenvironments on neurosecretory cells. Biomaterials. 2006 Jun; 27(16):3075-83. View in PubMed
- Benzel EC, Kayanja M, Fleischman A, Roy S. Spine biomechanics: fundamentals and future. Clin Neurosurg. 2006; 53:98-105. View in PubMed
- Mata A, Fleischman AJ, Roy S. Characterization of polydimethylsiloxane (PDMS) properties for biomedical micro/nanosystems. Biomed Microdevices. 2005 Dec; 7(4):281-93. View in PubMed
- Nath P, Roy S, Conlisk T, Fleischman AJ. A system for micro/nano fluidic flow diagnostics. Biomed Microdevices. 2005 Sep; 7(3):169-77. View in PubMed
- Benzel E, Ferrara L, Roy S, Fleischman A. Micromachines in spine surgery. Spine (Phila Pa 1976). 2004 Mar 15; 29(6):601-6. View in PubMed
- Mata A, Su X, Fleischman AJ, Roy S, Banks BA, Miller SK, Midura RJ. Osteoblast attachment to a textured surface in the absence of exogenous adhesion proteins. IEEE Trans Nanobioscience. 2003 Dec; 2(4):287-94. View in PubMed
- Mata A, Boehm C, Fleischman AJ, Muschler G, Roy S. Growth of connective tissue progenitor cells on microtextured polydimethylsiloxane surfaces. J Biomed Mater Res. 2002 Dec 15; 62(4):499-506. View in PubMed
- Mata A, Boehm C, Fleischman AJ, Muschler G, Roy S. Analysis of connective tissue progenitor cell behavior on polydimethylsiloxane smooth and channel micro-textures. Biomed Microdevices. 2002 Dec; 4(4):267-75. View in PubMed
- Kotzar G, Freas M, Abel P, Fleischman A, Roy S, Zorman C, Moran JM, Melzak J. Evaluation of MEMS materials of construction for implantable medical devices. Biomaterials. 2002 Jul; 23(13):2737-50. View in PubMed
- Benzel EC, Ferrara LA, Roy S, Fleischman AJ. Biomaterials and implantable devices: discoveries in the spine surgery arena. Clin Neurosurg. 2002; 49:209-25. View in PubMed